This page covers the second and fourth steps of the workflow: building stimulus protocols and running analysis on the recorded results.

Clamp modes

A simulation runs in one of two modes, identified by the constants neuroclamp.CURRENT_CLAMP ("Current Clamp") and neuroclamp.VOLTAGE_CLAMP ("Voltage Clamp"):

  • Current clamp injects a current waveform and records the resulting membrane voltage (and the underlying channel currents and gating variables).
  • Voltage clamp holds the membrane at a commanded voltage waveform and records the ionic currents required to clamp it.

Current-clamp protocols

The available current-clamp protocol types are listed in neuroclamp.CURRENT_PROTOCOLS:

Type Builder Description
Step step_current A constant current step between two times.
Ramp ramp_current A linearly increasing (or decreasing) current.
Pulse Train pulse_train A repeating train of brief current pulses.
Sinusoidal sinusoidal_current A sine wave on a DC offset.
Chirp chirp_current A swept-frequency sine (ZAP) for impedance probing.
Noise noise_current Gaussian white-noise current.

The low-level builders (step_current, ramp_current, ...) return a single 1-D stimulus array ready to pass straight to simulate_current_clamp. The higher-level build_current_protocol(protocol_type, sampling_frequency, ...) dispatches to them by name with a uniform keyword interface.

Voltage-clamp protocols

The available voltage-clamp protocol types are listed in neuroclamp.VOLTAGE_PROTOCOLS:

Type Builder Description
Step step_voltage A holding potential stepped to a test potential.
Ramp ramp_voltage A linear voltage ramp (for I-V curves).
Pulse Train pulse_train_voltage A repeating train of voltage pulses.
Inactivation (two-pulse protocol) A conditioning prepulse then a fixed test pulse, for steady-state inactivation (h-infinity).

The dispatcher is build_voltage_protocol(protocol_type, ...). The steady-state-inactivation protocol type is named by neuroclamp.INACTIVATION_PROTOCOL ("Inactivation").

Protocol presets

For ready-made experiments, build_protocol_from_preset composes a named protocol preset with a neuron's per-cell adjustments:

import neuroclamp

# (protocol preset name, neuron preset name)
protocol = neuroclamp.build_protocol_from_preset(
    "F-I Curve", "Cortical Pyramidal Neuron"
)

The protocol-preset names are in neuroclamp.PROTOCOL_PRESET_NAMES: Action Potential, Subthreshold Response, Repetitive Firing, F-I Curve, Hyperpolarization Steps, I-V Curve, Na+ Channel Activation, Steady-State Inactivation, and Frequency Response. These are the presets exposed in the UI's protocol picker.

Unlike the single-sweep builders, build_protocol_from_preset returns a 2-D array shaped (sweeps, samples) — multi-sweep protocols such as an F-I or I-V series produce one row per sweep, driven by the multi-sweep runner.

Running simulations

The two core runners take a Neuron and a stimulus array:

result = neuroclamp.simulate_current_clamp(neuron, current_external=stimulus)
result = neuroclamp.simulate_voltage_clamp(neuron, voltage_protocol=command)

Both return a SimulationResult — a NumPy structured array whose fields include time, voltage, the total membrane current Itotal, one current field per channel, and the gating variables. Related entry points:

  • simulate_current_clamp_from_state / simulate_voltage_clamp_from_state — resume a simulation from a saved gating state (used for continuous mode).
  • simulate_batch — run many protocols efficiently.

Analysis

The neuroclamp.analysis subpackage turns a recorded trace into physiological metrics. Each family has a high-level entry point and a typed result object.

  • Action potentials — analyze_aps(time, voltage) returns an APAnalysisResult (spike_count, firing_rate, per-spike SpikeMetrics, inter-spike intervals, mean peak/threshold/half-width/AHP).
  • F-I curves — analyze_fi builds a firing-rate-vs-current curve; estimate_rheobase finds the firing threshold; compute_fi_point scores one sweep.
  • I-V curves — analyze_iv / compute_iv_point build a current-vs-voltage curve from a voltage-clamp series.
  • Activation (G-V) curves — compute_gv builds a conductance-vs-voltage curve and boltzmann fits it, returning a BoltzmannFit.
  • Steady-state inactivation — compute_inactivation builds the h-infinity curve from the two-pulse inactivation protocol.
  • Bursting — analyze_bursts detects bursts and reports BurstMetrics (intra-burst rate, spikes per burst, burst duration).
  • Calcium transients — analyze_calcium_transients detects calcium transients and fits their decay (for presets with calcium dynamics).
  • Sag and rebound — analyze_hyperpolarization / compute_sag_point quantify Ih-driven sag and post-inhibitory rebound.
  • Impedance — analyze_impedance computes an impedance profile from a chirp (ZAP) protocol; impedance_unavailable_reason explains when it cannot.
  • Spike-frequency adaptation — analyze_sfa / compute_sfa quantify ISI growth across a sustained train.
  • Membrane time constant (tau-V) — analyze_tau_v / compute_tau_v_point fit exponential relaxations from voltage-clamp steps.
  • Passive properties — analyze_passive_properties and run_membrane_test measure input resistance, capacitance, and membrane time constant, returning PassiveProperties.

A minimal current-clamp-then-analyze example is in the overview. For full signatures and the result-object fields, see the API reference section of this site.